Enter the word you want to search
 
Power and Control Cables
NEWS
MAIL LIST
Name Surname
E-Mail
 
 
Array
(
    [urun_id] => 177
    [urun_ad] => Current Carrying Capacities
    [urun_kategori_id] => 331
    [urun_timestamp] => 1259150473
    [urun_durum] => 31
    [urun_aciklama] => 

Current - Carrying Capacities

To VDE 0100, part 430
 
  Current-Carrying Capacities According To Cross-Sections Of Conductors
   (For copper conductors and up to 30°C ambient temparatures)
 
Rated
cross-section
Group 1
Group 2
Group 3
Copper conductor
Copper conductor
Copper conductor
Cont. loading
Fuse   loading
Cont. loading
Fuse   loading
Cont. loading
Fuse   loading
mm²
A
A
A
A
A
A
    0,08
    0,8
-
    1,0
-
    1,5
-
    0,14
    1,5
-
    2,0
-
    3,0
-
    0,25
    3,0
-
    4,0
-
    5,0
-
    0,34
    4,5
-
    6,0
-
    8,0
-
    0,50
    7,0
-
    9,0
-
 12,0
-
    0,75
    9,0
-
 12,0
    6,0
 15,0
 10,0
    1,00
 11,0
    6,0
 15,0
 10,0
 19,0
 10,0
    1,50
 15,0
 10,0
 18,0
 10,0
 24,0
 20,0
    2,50
 20,0
 16,0
 26,0
 20,0
 32,0
 25,0
    4,00
 25,0
 20,0
 34,0
 25,0
 42,0
 35,0
    6,00
 33,0
 25,0
 44,0
 35,0
 54,0
 50,0
 10,00
 45,0
 35,0
 61,0
 50,0
 73,0
 63,0
 16,00
 61,0
 50,0
 82,0
 63,0
 98,0
 80,0
 25,00
 83,0
 63,0
108,0
 80,0
129,0
100,0
 35,00
103,0
 80,0
135,0
100,0
158,0
125,0
 50,00
132,0
100,0
168,0
125,0
198,0
160,0
 70,00
165,0
125,0
207,0
160,0
245,0
200,0
 95,00
197,0
160,0
250,0
200,0
292,0
250,0
120,00
235,0
200,0
292,0
250,0
344,0
315,0
150,00
-
-
335,0
250,0
391,0
315,0
Group 1 : One or more single-core cables in conduit.
Group 2: Multi-core outer sheathed cables for connecting portable appliances.
Group 3 : Single-core cable used in main and distribution switch boards and for connection at open air.
[urun_fiyat] => undefined YTL [urun_kod] => 0 [urun_indirimli_fiyat] => [urun_vitrin] => 32 [urun_kampanya] => 32 [urun_ag] => 32 [urun_stok] => 31 [tarih] => [uye_gor] => 1 [urun_okunma] => 0 [urun_seo_name] => current-carrying-capacities [urun_seo_keyword] => [URL] => /urun/current-carrying-capacities.htm [UrunCatName] => Power Control Cables Technical Data [Photo] => /1259156174_emekkablo_banner.jpg [gorsel_yolu] => 1259156174_emekkablo_banner.jpg [files] => Array ( [0] => Array ( [dosya_id] => 77 [icerik_id] => [video_id] => [urun_id] => 177 [dosya_adi] => Current Carrying Capacities [dosya_yolu] => 1263797050_4-_CURRENT_-_CARRYING_CAPACITIES.pdf [dosya_resim] => [dosya_tip] => pdf [dosya_aciklama] => Current Carrying Capacities [dosya_siralama] => 1 [dosya_timestamp] => 1263797203 ) ) [pictures] => Array ( [0] => Array ( [gorsel_id] => 941 [user_id] => 0 [icerik_id] => 0 [thumnail_id] => 0 [urun_id] => 177 [urun_cat_id] => 0 [marka_id] => 0 [gorsel_adi] => [gorsel_yolu] => 1259156174_emekkablo_banner.jpg [gorsel_aciklama] => [gorsel_siralama] => 1 [gorsel_timestamp] => 1259156307 [Photo] => /1259156174_emekkablo_banner.jpg ) ) [OtherContents] => Array ( [0] => Array ( [urun_id] => 180 [urun_ad] => Conductor Make-Up [urun_kategori_id] => 331 [urun_timestamp] => 1259152626 [urun_durum] => 31 [urun_aciklama] =>
Conductor Make-up
VDE 0295 - IEC 228
 
· Number Of Wires and Diameters According To Cross-Sections Of Conductors
Cross-section
Strands
Multi-wire strands
Fine-wire strands
Extra fine-wire strands
Class 2
Class 5
Class 6
mm²
Column1
Column2
Column3
Column 4
Column 5
Column 6
Column 7
    0,14
-
    7x0,16
 ~18x0,10
 ~18x0,10
~18x0,10
   ~36x0,07
    ~72x0,05
    0,25
-
    7x0,21
 ~14x0,15
 ~32x0,10
~32x0,10
~65x0,07
 ~128x0,05
    0,34
-
    7x0,25
 ~19x0,15
 ~ 42x0,10
~42x0,10
~88x0,07
  ~174x0,05
    0,50
7x0,30
    7x0,30
 ~16x0,20
~28x0,15
~64x0,10
~100x0,07
 ~194x0,05
    0,75
7x0,37
    7x0,37
 ~24x0,20
 ~42x0,15
~96x0,10
~131x0,07
 ~256x0,05
    1,00
7x0,43
    7x0,43
 ~32x0,20
~56x0,15
~128x0,10
~195x0,07
 ~384x0,05
    1,50
7x0,52
    7x0,52
 ~30x0,25
~84x0,15
~192x0,10
~260x0,07
 ~512x0,05
    2,50
7x0,67
 19x0,41
 ~50x0,25
~140x0,15
~320x0,10
~392x0,07
 ~768x0,05
    4,00
7x0,85
 19x0,52
 ~56x0,30
~224x0,15
~512x0,10
~651x0,07
~1280x0,05
    6,00
7x1,05
 19x0,64
 ~84x0,30
~192x0,20
~768x0,10
~1040x0,07
-
 10,00
7x1,35
 49x0,51
 ~80x0,40
~320x0,20
~1280x0,10
~1560x0,07
-
 16,00
7x1,70
 49x0,65
~128x0,40
~512x0,20
~2048x0,10
~2600x0,07
-
 25,00
7x2,13
 84x0,62
~200x0,40
~800x0,20
~3200x0,10
-
-
 35,00
7x2,52
133x0,58
~280x0,40
~1120x0,20
-
-
-
 50,00
19x1,83
133x0,69
~400x0,40
~705x0,30
-
-
-
 70,00
19x2,17
189x0,69
~356x0,50
~990x0,30
-
-
-
 95,00
19x2,52
259x0,69
~485x0,50
~1340x0,30
-
-
-
120,00
37x2,03
336x0,67
~614x0,50
~1690x0,30
-
-
-
150,00
27x2,27
392x0,69
~765x0,50
~2123x0,30
-
-
-
Class 2: Multi-wire copper conductor for single and multi-core cables,
Class 5: Fine-wire copper conductor for single and multi-core cables,
Class 6: Extra fine-wire copper conductor for single and multi-core cables.
[urun_fiyat] => undefined YTL [urun_kod] => 0 [urun_indirimli_fiyat] => [urun_vitrin] => 32 [urun_kampanya] => 32 [urun_ag] => 32 [urun_stok] => 31 [tarih] => [uye_gor] => 1 [urun_okunma] => 0 [urun_seo_name] => conductor-make-up [urun_seo_keyword] => [URL] => /urun/conductor-make-up.htm [Photo] => /1259156174_emekkablo_banner.jpg [gorsel_yolu] => 1259156174_emekkablo_banner.jpg ) [1] => Array ( [urun_id] => 179 [urun_ad] => Conductor Resistance [urun_kategori_id] => 331 [urun_timestamp] => 1259152273 [urun_durum] => 31 [urun_aciklama] =>

Conductor Resistance
TS 6570 - HD 383 - VDE 0295 - IEC 228

 

· Max. Resistance In D.C. According To Cross-Sections Of Conductors
   (For copper conductors to 20°C)
 
Rated
Bare copper wire
Tinned copper wire
 
cross-section
Class
1 and 2
Class
5 and 6
Class
1 and 2
Class
5 and 6
Bare
copper wire
Tinned
copper wire
mm²
Ohm / km
Ohm / km
Ohm / km
Ohm / km
Ohm / km
Ohm / km
    0,05
-
~380
-
~392
-
-
    0,08
-
~237
-
~244
-
-
    0,11
-
~170
-
~175
-
-
     0,126
-
~150
-
~155
-
-
    0,14
-
~134
-
~138
-
-
    0,22
-
~96
-
~99
-
-
    0,25
-
~76
-
~79
-
-
    0,34
-
~53
-
~56
-
-
    0,50
36
39
36,7
40,1
-
-
    0,75
24,5
26
24,8
26,7
-
-
    1,00
18,1
19,5
18,2
20,0
-
-
    1,50
12,1
13,3
12,2
13,7
-
-
    2,50
7,41
7,98
7,56
8,21
-
-
    4,00
4,61
4,95
4,70
5,09
-
-
    6,00
3,08
3,30
3,11
3,39
-
-
   10,00
1,83
1,91
1,84
1,95
-
-
   16,00
1,15
1,21
1,16
1,24
1,16
1,19
   25,00
0,727
0,780
0,734
0,795
0,758
0,780
   35,00
0,524
0,554
0,529
0,565
0,536
0,552
   50,00
0,387
0,386
0,391
0,393
0,379
0,390
   70,00
0,268
0,272
0,270
0,277
0,268
0,276
   95,00
0,193
0,206
0,195
0,210
0,198
0,204
 120,00
0,153
0,161
0,154
0,164
0,155
0,159
 150,00
0,124
0,129
0,126
0,132
0,125
0,129
Class 1: Single-wire copper conductor for single and multi-core cables,
Class 2: Multi-wire copper conductor for single and multi-core cables,
Class 5: Fine-wire copper conductor for single and multi-core cables,
Class 6: Extra fine-wire copper conductor for single and multi-core cables. 
[urun_fiyat] => undefined YTL [urun_kod] => 0 [urun_indirimli_fiyat] => [urun_vitrin] => 32 [urun_kampanya] => 32 [urun_ag] => 32 [urun_stok] => 31 [tarih] => [uye_gor] => 1 [urun_okunma] => 0 [urun_seo_name] => conductor-resistance [urun_seo_keyword] => [URL] => /urun/conductor-resistance.htm [Photo] => /1259156174_emekkablo_banner.jpg [gorsel_yolu] => 1259156174_emekkablo_banner.jpg ) [2] => Array ( [urun_id] => 178 [urun_ad] => Colours of Cable Cores [urun_kategori_id] => 331 [urun_timestamp] => 1259151112 [urun_durum] => 31 [urun_aciklama] =>

Colour Of Cable Cores

 
prHD 308 S2
Number Of Cores
Colour Of Cores
With protective conductor
Without protective conductor
1
Green/Yellow
Any colour
2
-
Blue - Brown
3
Green/Yellow - Blue - Brown
Black - Blue - Brown
4
Green/Yellow - Black - Blue - Brown
Black - Blue - Brown - Black
5
Green/Yellow - Black - Blue - Brown - Black
Black - Blue - Brown - Black - Black
6 or more
Green/Yellow and all outhers black coloured white number printed
All the cores black coloured and white number printed
 
NLSY & NLSCY
DIN VDE 0245
Core
Colour
Core
Colour
Core
Colour
 1
White
21
White-Blue
41
Grey-Black
 2
Brown
22
Brown-Blue
42
Pink-Black
 3
Green
23
White-Red
43
Blue-Black
 4
Yellow
24
Brown-Red
44
Red-Black
 5
Grey
25
White-Black
45
White-Brown-Black
 6
Pink
26
Brown-Black
46
Yellow-Green-Black
 7
Blue
27
Grey-Green
47
Grey-Pink-Black
 8
Red
28
Yellow-Grey
48
Red-Blue-Black
 9
Black
29
Pink-Green
49
White-Green-Black
10
Violet
30
Yellow-Pink
50
Brown-Green-Black
11
Grey-Pİnk
31
Green-Blue
51
White-Yellow-Black
12
Red-Blue
32
Yellow-Blue
52
Yellow-Brown-Black
13
White-Green
33
Green-Red
53
White-Grey-Black
14
Brown-Green
34
Yellow-Red
54
Grey-Brown-Black
15
White-Yellow
35
Green-Black
55
White-Pink-Black
16
Yellow-Brown
36
Yellow-Black
56
Pink-Brown-Black
17
White-Grey
37
Grey-Blue
57
White-Blue-Black
18
Grey-Brown
38
Pink-Blue
58
Brown-Blue-Black
19
White-Pink
39
Grey-Red
59
White-Red-Black
20
Pink-Brown
40
Pink-Red
60
Brown-Red-Black
 
Example
 
Core          57 White - Blue-Black
                           a             b      
 
a- Basic colour

b- Ring colour

 

[urun_fiyat] => undefined YTL [urun_kod] => 0 [urun_indirimli_fiyat] => [urun_vitrin] => 32 [urun_kampanya] => 32 [urun_ag] => 32 [urun_stok] => 31 [tarih] => [uye_gor] => 1 [urun_okunma] => 0 [urun_seo_name] => colours-of-cable-cores [urun_seo_keyword] => [URL] => /urun/colours-of-cable-cores.htm [Photo] => /1259156174_emekkablo_banner.jpg [gorsel_yolu] => 1259156174_emekkablo_banner.jpg ) [3] => Array ( [urun_id] => 177 [urun_ad] => Current Carrying Capacities [urun_kategori_id] => 331 [urun_timestamp] => 1259150473 [urun_durum] => 31 [urun_aciklama] =>

Current - Carrying Capacities

To VDE 0100, part 430
 
  Current-Carrying Capacities According To Cross-Sections Of Conductors
   (For copper conductors and up to 30°C ambient temparatures)
 
Rated
cross-section
Group 1
Group 2
Group 3
Copper conductor
Copper conductor
Copper conductor
Cont. loading
Fuse   loading
Cont. loading
Fuse   loading
Cont. loading
Fuse   loading
mm²
A
A
A
A
A
A
    0,08
    0,8
-
    1,0
-
    1,5
-
    0,14
    1,5
-
    2,0
-
    3,0
-
    0,25
    3,0
-
    4,0
-
    5,0
-
    0,34
    4,5
-
    6,0
-
    8,0
-
    0,50
    7,0
-
    9,0
-
 12,0
-
    0,75
    9,0
-
 12,0
    6,0
 15,0
 10,0
    1,00
 11,0
    6,0
 15,0
 10,0
 19,0
 10,0
    1,50
 15,0
 10,0
 18,0
 10,0
 24,0
 20,0
    2,50
 20,0
 16,0
 26,0
 20,0
 32,0
 25,0
    4,00
 25,0
 20,0
 34,0
 25,0
 42,0
 35,0
    6,00
 33,0
 25,0
 44,0
 35,0
 54,0
 50,0
 10,00
 45,0
 35,0
 61,0
 50,0
 73,0
 63,0
 16,00
 61,0
 50,0
 82,0
 63,0
 98,0
 80,0
 25,00
 83,0
 63,0
108,0
 80,0
129,0
100,0
 35,00
103,0
 80,0
135,0
100,0
158,0
125,0
 50,00
132,0
100,0
168,0
125,0
198,0
160,0
 70,00
165,0
125,0
207,0
160,0
245,0
200,0
 95,00
197,0
160,0
250,0
200,0
292,0
250,0
120,00
235,0
200,0
292,0
250,0
344,0
315,0
150,00
-
-
335,0
250,0
391,0
315,0
Group 1 : One or more single-core cables in conduit.
Group 2: Multi-core outer sheathed cables for connecting portable appliances.
Group 3 : Single-core cable used in main and distribution switch boards and for connection at open air.
[urun_fiyat] => undefined YTL [urun_kod] => 0 [urun_indirimli_fiyat] => [urun_vitrin] => 32 [urun_kampanya] => 32 [urun_ag] => 32 [urun_stok] => 31 [tarih] => [uye_gor] => 1 [urun_okunma] => 0 [urun_seo_name] => current-carrying-capacities [urun_seo_keyword] => [URL] => /urun/current-carrying-capacities.htm [Photo] => /1259156174_emekkablo_banner.jpg [gorsel_yolu] => 1259156174_emekkablo_banner.jpg ) ) )
»Current Carrying Capacities
 

Current - Carrying Capacities

To VDE 0100, part 430
 
  Current-Carrying Capacities According To Cross-Sections Of Conductors
   (For copper conductors and up to 30°C ambient temparatures)
 
Rated
cross-section
Group 1
Group 2
Group 3
Copper conductor
Copper conductor
Copper conductor
Cont. loading
Fuse   loading
Cont. loading
Fuse   loading
Cont. loading
Fuse   loading
mm²
A
A
A
A
A
A
    0,08
    0,8
-
    1,0
-
    1,5
-
    0,14
    1,5
-
    2,0
-
    3,0
-
    0,25
    3,0
-
    4,0
-
    5,0
-
    0,34
    4,5
-
    6,0
-
    8,0
-
    0,50
    7,0
-
    9,0
-
 12,0
-
    0,75
    9,0
-
 12,0
    6,0
 15,0
 10,0
    1,00
 11,0
    6,0
 15,0
 10,0
 19,0
 10,0
    1,50
 15,0
 10,0
 18,0
 10,0
 24,0
 20,0
    2,50
 20,0
 16,0
 26,0
 20,0
 32,0
 25,0
    4,00
 25,0
 20,0
 34,0
 25,0
 42,0
 35,0
    6,00
 33,0
 25,0
 44,0
 35,0
 54,0
 50,0
 10,00
 45,0
 35,0
 61,0
 50,0
 73,0
 63,0
 16,00
 61,0
 50,0
 82,0
 63,0
 98,0
 80,0
 25,00
 83,0
 63,0
108,0
 80,0
129,0
100,0
 35,00
103,0
 80,0
135,0
100,0
158,0
125,0
 50,00
132,0
100,0
168,0
125,0
198,0
160,0
 70,00
165,0
125,0
207,0
160,0
245,0
200,0
 95,00
197,0
160,0
250,0
200,0
292,0
250,0
120,00
235,0
200,0
292,0
250,0
344,0
315,0
150,00
-
-
335,0
250,0
391,0
315,0
Group 1 : One or more single-core cables in conduit.
Group 2: Multi-core outer sheathed cables for connecting portable appliances.
Group 3 : Single-core cable used in main and distribution switch boards and for connection at open air.


Colours of Cable Cores

Conductor Resistance

Conductor Make-Up